High Temperature Accelerometers >900°C
A unique device specifically developed for exhaust and turbo charger testing where surface temperatures can exceed 900°C. As the only fully integrated device on the market it offers unrivalled reliability and repeatability under the most extreme conditions. Using a simple water pump (usually a car windscreen washer pump) requiring just 0.5ltr/min flow the operation is both simple and effective.
With no reduction in operating temperature, even using the IEPE voltage output version, DJB lead the world in this application.
Model | Image | Sensitivity | Weight | Temperature Range |
---|---|---|---|---|
Triaxial Charge High Temperature Accelerometers | ||||
A/33 - Flat Base, A/33-1 - Raised Base | 7pC/g nom. | 38gm | -50°C to 900°C Max Temp WITH WATER FLOW |
Model | Image | Sensitivity | Weight | Temperature Range |
---|---|---|---|---|
Triaxial IEPE High Temperature Accelerometers | ||||
A/133/V-3 - Flat base; A/133/V-10 Raised base | 1mV/g up to 250mV/g | 38gm/46gm | -50°C to 900°C Max Temp WITH WATER FLOW |